A DOMESTIC BORE WATER TREATMENT PROCESS USING REVERSE OSMOSIS APPLICATION


- Short membrane life
- Poor rejection and recovery
- Requirement for a membrane change out
The plant was audited by All Purpose Pumps and found to have several typical design and process faults –
- Media filter backwash was incorrectly set up and was causing a significant impact on the efficiency of the backwash cycle. So much so that initially, the media filter DP was more than 160-kPa
- The antiscalant dosing was set up incorrectly resulting in intermittent and incorrect operation of the dosing pump.
- This led to the RO membranes being scaled to the point where permeate flow was negligible and salt rejection was around 50%. This scaling had led to scale forming on various pieces of components as well – for example, all concentrate flow lines including the VA flow meters.
- The owner was at the point of discontinuing the plant and shutting it down permanently due to the lack of return with this process over the cost of Mains water and it was not economically sustainable.
Subsequently, the process has been modified and attended to in the form of –
- Pre-treatment backwash is no longer compromised by the RO cycles. Media filter backwash cycle is now effective and has no tangible impact on the RO performance in the form of poor backwash performance and media filter DP is now 20-kPa
- Antiscalent dosing was rectified with the correct setting and tuning of the dosing pump, two long term minor leaks leading to partial cavitation of the dosing pump were also rectified. Dosing is now consistent in delivery.
- Membranes were replaced as they were scaled beyond recovery.
- Salt rejection – >99%
- System recovery – conservatively set at 65%
- System operating pressure reduced by 25%
The plant is now running smoothly, consistently and reliably. Routine servicing including effective membrane cleaning and antiscalant calibration shall ensure a long serviceable life.